General Information
Extended Product Type:AF09-30-01-13
Product ID:1SBL137001R1301
EAN:3471523110137
Extended Product Type:AF09-30-01-13
Product ID:1SBL137001R1301
EAN:3471523110137
Catalog Description:AF09-30-01-13 100-250V50/60HZ-DC Contactor
Long Description:AF09 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available.
Categories
Products » Low Voltage Products and Systems » Control Products » Contactors » Block Contactors
AF09-30-01-13 - image 0
Ordering
Minimum Order Quantity:1 piece
Customs Tariff Number:85364900
Popular Downloads
Instructions and Manuals:1SBC101027M6801
Dimensions
Product Net Width:45 mm
Product Net Depth / Length:77 mm
Product Net Height:86 mm
Product Net Weight:0.27 kg
Technical
Number of Main Contacts NO:3
Number of Main Contacts NC:0
Number of Auxiliary Contacts NO:0
Number of Auxiliary Contacts NC:1
Standards:IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
Rated Operational Voltage:Auxiliary Circuit 690 V
Main Circuit 690 V
Rated Frequency (f):Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):acc. to IEC 60947-5-1, q = 40 °C 16 A
acc. to IEC 60947-4-1, Open Contactors q = 40 °C 35 A
Rated Operational Current AC-1 (Ie):(690 V) 40 °C 25 A
(690 V) 60 °C 25 A
(690 V) 70 °C 22 A
Rated Operational Current AC-3 (Ie):(220 / 230 / 240 V) 60 °C 9 A
(380 / 400 V) 60 °C 9 A
(415 V) 60 °C 9 A
(440 V) 60 °C 9 A
(500 V) 60 °C 9.5 A
(690 V) 60 °C 7 A
Rated Operational Power AC-3 (Pe):(220 / 230 / 240 V) 2.2 KWT
(380 / 400 V) 4 KWT
(415 V) 4 KWT
(440 V) 4 KWT
(500 V) 5.5 KWT
(690 V) 5.5 KWT
(400 V) 4 KWT
Rated Operational Current AC-15 (Ie):(220 / 240 V) 4 A
(24 / 127 V) 6 A
(500 V) 2 A
(690 V) 2 A
(400 / 440 V) 3 A
Rated Short-time Withstand Current (Icw):at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
for 0.1 s 140 A
for 1 s 100 A
Maximum Breaking Capacity:cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Maximum Electrical Switching Frequency:AC-1 600 cycles per hour
AC-2 / AC-4 300 cycles per hour
AC-3 1200 cycles per hour
AC-15 1200 cycles per hour
DC-13 900 cycles per hour
Rated Operational Current DC-13 (Ie):(125 V) 0.55 A / 69 W
(24 V) 6 A / 144 W
(250 V) 0.27 A / 68 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 0.55 A / 60 W
(220 V) 0.27 A / 60 W
(400 V) 0.15 A / 60 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
Rated Insulation Voltage (Ui):acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp):6 kV
Maximum Mechanical Switching Frequency:3600 cycles per hour
Rated Control Circuit Voltage (Uc):50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
Operate Time:Between Coil De-energization and NC Contact Closing 13 ... 98 ms
Between Coil De-energization and NO Contact Opening 11 ... 95 ms
Between Coil Energization and NC Contact Opening 38 ... 90 ms
Between Coil Energization and NO Contact Closing 40 ... 95 ms
Connecting Capacity Main Circuit:Rigid 1/2x 1 ... 6 m²
Flexible with Ferrule 1/2x 0.75 ... 6 m²
Flexible with Insulated Ferrule 1x 0.75 ... 4 m²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 m²
Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 ... 2.5 m²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 m²
Rigid 1/2x 1 ... 2.5 m²
Connecting Capacity Control Circuit:Flexible with Ferrule 1/2x 0.75 ... 2.5 m²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 m²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 m²
Rigid 1/2x 1 ... 2.5 m²
Wire Stripping Length:Auxiliary Circuit 10 mm
Control Circuit 10 mm
Main Circuit 10 mm
Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Terminal Type:Screw Terminals
Environmental
Ambient Air Temperature:Close to Contactor for Storage -60 ... +80 °C
Close to Contactor without Thermal O/L Relay -40 ... +70 °C
Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C
Climatic Withstand:Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible:3000 m
Resistance to Vibrations acc. to IEC 60068-2-6:5 ... 300 Hz 4 g closed position / 2 g open position
Resistance to Shock acc. to IEC 60068-2-27:Shock Direction: A 30 K40
Shock Direction: B2 15 K40
Shock Direction: C1 25 K40
Shock Direction: C2 25 K40
Closed, Shock Direction: B1 25 K40
Open, Shock Direction: B1 5 K40
RoHS Status:Following EU Directive 2011/65/EU
Technical UL/CSA
General Use Rating UL/CSA:(600 V AC) 25 A
Horsepower Rating UL/CSA:(220 ... 240 V AC) Three Phase 2 hp
(440 ... 480 V AC) Three Phase 5 hp
(550 ... 600 V AC) Three Phase 7-1/2 hp
(120 V AC) Single Phase 3/4 hp
(200 ... 208 V AC) Three Phase 2 hp
(240 V AC) Single Phase 1-1/2 hp
Tightening Torque UL/CSA:Auxiliary Circuit 11 IA
Control Circuit 11 IA
Main Circuit 13 IA
Certificates and Declarations (Document Number)
ABS Certificate:ABS_15-GE1349500-PDA_90682247
BV Certificate:BV_2634H24898B0
CB Certificate:CB_SE-80871M3
CCC Certificate:CCC_2010010304445624
cUL Certificate:UL_20180227_E312527_7_1
Declaration of Conformity - CE:1SBD250000U1000
DNV Certificate:DNV-GL_TAE00001AF-3
DNV GL Certificate:DNV-GL_TAE00001AF-3
EAC Certificate:EAC_RU C-FR ME77 B03597
Environmental Information:1SBD250147E1000
GL Certificate:DNV-GL_TAE00001AF-3
GOST Certificate:GOST_POCCFR.ME77.B07175.pdf
Instructions and Manuals:1SBC101027M6801
KC Certificate:KC_HW02016-15004A
LR Certificate:LRS_1300087E1
RINA Certificate:RINA_ELE240318XG
RMRS Certificate:RMRS_1802705280
RoHS Information:1SBD250000U1000
UL Certificate:UL_20140305-E312527_7_1
UL Listing Card:E312527
Container Information
Package Level 1 Units:box 1 piece
Package Level 1 Width:87 mm
Package Level 1 Depth / Length:79 mm
Package Level 1 Height:47 mm
Package Level 1 Gross Weight:0.27 kg
Package Level 1 EAN:3471523110137
Package Level 2 Units:27 piece
Package Level 2 Width:250 mm
Package Level 2 Depth / Length:300 mm
Package Level 2 Height:315 mm
Package Level 2 Gross Weight:7.29 kg
Package Level 3 Units:1296 piece
Classifications
Object Classification Code:Q
ETIM 4:EC000066 - Magnet contactor, AC-switching
ETIM 5:EC000066 - Magnet contactor, AC-switching
ETIM 6:EC000066 - Power contactor, AC switching
ETIM 7:EC000066 - Power contactor, AC switching
Trên đây là một số những thông tin giúp các bạn hiểu hơn về máy tính công nghiệp. Cần thêm thông tin gì các bạn cứ liên hệ H-Fast nhé!
"HFAST -Thiết Công Nghiệp tốt nhất với giá CẠNH TRANH nhất!"
Quý khách hàng liên hệ :
CTY TNHH H-FAST VIỆT NAM
- ĐC: Số 15 ngõ 268 lê trọng tấn thanh xuân Hà Nôi ( gần đại học y Hà Nội )
- Tổng đài: 024.7309.8989
- Cố định : 024.224.224.00
- Di động: 0978. 748. 468
- Kế toán : 0988. 983. 873
(Zalo cùng số )
- Bạn sẽ được Tư vấn giải pháp lắp đặt tốt nhất cho nhà xưởng ,với chi phí hợp với túi tiền của bạn nhất
- Văn phòng liên hệ số 15 ngõ 268 lê trọng tấn thanh xuân Hà Nôi ( gần đại học y Hà Nội )
· kho hàng số 22 ngách 43/98 ngõ 110 Trần Duy Hưng- Phường Trung Hòa - Quận Cầu Giấy - TP Hà Nội