MOTOR STARTER 3P, 690VAC, AF116-30-11-13
Giá: Liên hệ
Thông tin sản phẩm
Mô tả sản phẩm
Extended Product Type:AF116-30-11-13
Product ID:1SFL427001R1311
EAN:7320500476376
Catalog Description:AF116-30-11-13 Contactor
Long Description:A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V. Operated with wide control voltage range 100-250 V, 50/60 Hz and DC
Ordering
-
- Minimum Order Quantity:
- 1 piece
-
- Customs Tariff Number:
- 85364900
Popular Downloads
-
- Data Sheet, Technical Information:
- 1SBC100192C0206
-
- Instructions and Manuals:
- 1SFC100003M0201
-
- Dimension Diagram:
- 1SFB535001G1051
Dimensions
-
- Product Net Width:
- 90 mm
-
- Product Net Depth / Length:
- 126 mm
-
- Product Net Height:
- 150 mm
-
- Product Net Weight:
- 1.644 kg
Technical
-
- Number of Main Contacts NO:
- 3
-
- Number of Main Contacts NC:
- 0
-
- Number of Auxiliary Contacts NO:
- 1
-
- Number of Auxiliary Contacts NC:
- 1
-
- Rated Operational Voltage:
- Main Circuit 690 V
-
- Rated Frequency (f):
- Main Circuit 50/60 Hz
-
- Conventional Free-air Thermal Current (Ith):
- acc. to IEC 60947-4-1, Open Contactors q = 40 °C 160 A
-
- Rated Operational Current AC-1 (Ie):
- (690 V) 55 °C 145 A
(690 V) 40 °C 160 A
(690 V) 70 °C 130 A
-
- Rated Operational Current AC-3 (Ie):
- (690 V) 55 °C 65 A
(415 V) 55 °C 116 A
(220 / 230 / 240 V) 55 °C 116 A
(440 V) 55 °C 116 A
(380 / 400 V) 55 °C 116 A
(500 V) 55 °C 110 A
-
- Rated Operational Power AC-3 (Pe):
- (220 / 230 / 240 V) 30 kW
(380 / 400 V) 55 kW
(415 V) 55 kW
(440 V) 75 kW
(500 V) 75 kW
(690 V) 55 kW
-
- Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
- 8 x Ie AC-3
-
- Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
- 10 x Ie AC-3
-
- Short-Circuit Protective Devices:
- gG Type Fuses 250 A
-
- Rated Short-time Withstand Current (Icw):
- at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 A
-
- Maximum Breaking Capacity:
- cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1000 A
-
- Maximum Electrical Switching Frequency:
- AC-3 300 cycles per hour
AC-1 300 cycles per hour
AC-2 / AC-4 150 cycles per hour
-
- Rated Operational Current DC-1 (Ie):
- (110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
-
- Rated Operational Current DC-3 (Ie):
- (110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
-
- Rated Operational Current DC-5 (Ie):
- (110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
-
- Rated Insulation Voltage (Ui):
- acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
-
- Rated Impulse Withstand Voltage (Uimp):
- Main Circuit 8 kV
-
- Mechanical Durability:
- 5 million
-
- Maximum Mechanical Switching Frequency:
- 300 cycles per hour
-
- Coil Operating Limits:
- (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C
-
- Rated Control Circuit Voltage (Uc):
- 60 Hz 100 ... 250 V
50 Hz 100 ... 250 V
DC Operation 100 ... 250 V
-
- Coil Consumption:
- Pull-in at Max. Rated Control Circuit Voltage 60 Hz 130 V·A
Holding at Max. Rated Control Circuit Voltage DC 3 W
Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 135 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 130 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 6 V·A
-
- Operate Time:
- Between Coil De-energization and NO Contact Opening 37 ... 47 ms
Between Coil Energization and NO Contact Closing 25 ... 55 ms
-
- Connecting Capacity Main Circuit:
- Flexible 2 x 10 ... 70 mm²
Rigid Cu-Cable 2 x 10 ... 95 mm²
-
- Connecting Capacity Auxiliary Circuit:
- Solid 2 x 1 ... 4 mm²
Flexible with Insulated Ferrule 1 x 0.75 ... 2.5 mm²
Stranded 2 x 1 .... 4 mm²
Flexible 2x0.75 ... 2.5 mm²
Flexible with Ferrule 2 x 0.75 ... 2.5 mm²
-
- Degree of Protection:
- acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
-
- Terminal Type:
- Double Clamp
Environmental
-
- Ambient Air Temperature:
- Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... +50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +70 °C
Close to Contactor for Storage -40 ... +70 °C
-
- Maximum Operating Altitude Permissible:
- 3000 m
-
- RoHS Status:
- Following EU Directive 2011/65/EU
Technical UL/CSA
-
- Maximum Operating Voltage UL/CSA:
- Main Circuit 600 V
-
- General Use Rating UL/CSA:
- (600 V AC) 160 A
-
- Horsepower Rating UL/CSA:
- (208 V AC) Three Phase 30 Hp
(440 ... 480 V AC) Three Phase 75 Hp
(550 ... 600 V AC) Three Phase 100 Hp
(220 ... 240 V AC) Three Phase 40 Hp
(200 V AC) Three Phase 30 Hp
Certificates and Declarations (Document Number)
-
- ABS Certificate:
- 14-LD1092198-PDA
-
- BV Certificate:
- BV_36353_A0BV
-
- CB Certificate:
- SEMKO_SE-70479M1
-
- CCC Certificate:
- 2013010304604050
-
- CCS Certificate:
- GB14T00030
-
- cUL Certificate:
- 20120925-E36588
-
- Declaration of Conformity - CE:
- 2CMT2015-005439
-
- DNV Certificate:
- DNV_E-14043
-
- DNV GL Certificate:
- DNV_E-14043
-
- EAC Certificate:
- 9AKK107046A8618
-
- Environmental Information:
- 2CMT004732
-
- GL Certificate:
- DNV_E-14043
-
- Instructions and Manuals:
- 1SFC100003M0201
-
- LR Certificate:
- LR_14_70011(E1)
-
- PRS Certificate:
- TE_2092_880423_16
-
- RINA Certificate:
- ELE060313XG_002
-
- RMRS Certificate:
- 9AKK107045A6978
-
- RoHS Information:
- 2CMT2016-005489
-
- UL Listing Card:
- UL_E36588
Container Information
-
- Package Level 1 Units:
- box 1 piece
-
- Package Level 1 Width:
- 194 mm
-
- Package Level 1 Depth / Length:
- 115 mm
-
- Package Level 1 Height:
- 169 mm
-
- Package Level 1 Gross Weight:
- 1.57 kg
-
- Package Level 1 EAN:
- 7320500476376
Classifications
-
- Object Classification Code:
- Q
-
- ETIM 4:
- EC000066 - Magnet contactor, AC-switching
-
- ETIM 5:
- EC000066 - Magnet contactor, AC-switching
-
- ETIM 6:
- EC000066 - Power contactor, AC switching
-
- ETIM 7:
- EC000066 - Power contactor, AC switching